SECTION TSM 320.1
PAGE 1 Of 7
ISSUE E
VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 USA
TECHNICAL SERVICE MANUAL
CONTENTS
INTRODUCTION
The illustrations used in this maintenance bulletin are for
identification purposes only and should not be used for
ordering parts. Secure a parts list from the factory or a
Viking representative. Always give complete name of part,
part number and material with the model and serial number
of the pump when ordering repair parts.
FIGURE 1
SERIES 56M AND 456M PUMP
(3 GPM Size Shown)
Packed Or Mechanical Seal Type.
Valve On Casing - Clockwise Rotation
Introduction . . . . . . . . . . . . . . . . . . . . . . . 1
Special Information . . . . . . . . . . . . . . . . . . . 1
Pressure Relief Valves . . . . . . . . . . . . . . . . . 2
Maintenance . . . . . . . . . . . . . . . . . . . . . . 2
Disassembly . . . . . . . . . . . . . . . . . . . . . . 2
Installing Casing Bushing . . . . . . . . . . . . . . . . 4
Assembly . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Adjustment . . . . . . . . . . . . . . . . . . 5
Special Pump Designs . . . . . . . . . . . . . . . . . 5
UNMOUNTED PUMP UNITS
PACKED MECH. SEAL
Units are designated by the
unmounted pump model
numbers followed by a letter
indicating drive style.
M = Motor Mounted Unit
C56 C456
F56 F456
FH56 FH456
SPECIAL INFORMATION
DANGER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.)
Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor,
turbine, engine, etc.) has been “locked
out” or made non-operational so that
it cannot be started while work is
being done on pump.
3. That you know what liquid the
pump has been handling and the
precautions necessary to safely
handle the liquid. Obtain a material
safety data sheet (MSDS) for the
liquid to be sure these precautions
are understood.
Failure to follow above listed
precautionary measures may result in
serious injury or death.
This manual deals exclusively with Pump Models C, F,
FH56M and C, F, FH456M General Purpose Pumps. Refer
to Figures 1, 2, 4, and 7 for general configuration and
nomenclature used in this bulletin.
All pumps can be furnished with either a mechanical seal or
packing. Packed pumps are furnished with suitable packing
for the liquid pumped. A seal pump can be changed to a
packed pump by removing the mechanical seal and inserting
the packing spring, inner packing gland, packing and outer
packing gland. The mechanical seal pump is dimensionally
interchangeable with the packed pump.
Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com
GENERAL PURPOSE HUB MOUNTED PUMPS
SERIES 56 AND 456
SIZES C - F - FH
Page view 0
1 2 3 4 5 6 7

Summary of Contents

Page 1 - TECHNICAL SERVICE MANUAL

SECTION TSM 320.1PAGE 1 Of 7ISSUE EVIKING PUMP, INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USATECHNICAL SERVICE MANUAL CONTENTSINTR

Page 2

SECTION TSM 320.1 ISSUE E PAGE 2 OF 7BEFORE opening any liquid chamber (pumping chamber, reservoir, relief valve adjusting cap fitting, etc.) be su

Page 3 - DISASSEMBLY

SECTION TSM 320.1 ISSUE E PAGE 3 OF 7ROTATION: Viking pumps operate equally well in a clockwise or counterclockwise rotation. Shaft rotation determ

Page 4 - FIGURE 4

SECTION TSM 320.1 ISSUE E PAGE 4 OF 7FIGURE 2EXPLODED VIEW SERIES 56 AND 456ITEM NAME OF PART ITEM NAME OF PART ITEM NAME OF PART1 Electric Motor 1

Page 5 - ASSEMBLY

SECTION TSM 320.1 ISSUE E PAGE 5 OF 7The casing bushing can be replaced in the following manner: Insert a bar approximately 0.94” diameter and at l

Page 6 - PRESSURE RELIEF VALVE

SECTION TSM 320.1 ISSUE E PAGE 6 OF 7The relief valve is a pressure device to protect the pump and motor against excessive pressure. A pump withou

Page 7

SECTION TSM 320.1PAGE 7 OF 7ISSUE EVIKING PUMP, INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA© 3/2013 Viking Pump Inc. All rights