INTRODUCTION
Introduction . . . . . . . . . . . . . . . . . . . . . . . 1
Special Information . . . . . . . . . . . . . . . . . . . 1
Safety Information. . . . . . . . . . . . . . . . . . . . 2
Maintenance . . . . . . . . . . . . . . . . . . . . . . 3
Disassembly . . . . . . . . . . . . . . . . . . . . . . 3
Assembly . . . . . . . . . . . . . . . . . . . . . . . . 4
UNMOUNTED PUMP UNITS
F4625
Units are designated by the
unmounted pump model numbers
followed by a letter indicating
drive style.
V = V-Belt
D = Direct Connected
FH4625
The illustrations used in this manual are for identification
purposes only and should not be used for ordering parts.
Secure a parts list from the factory or a Viking representative.
Always give complete name of part, part number and material
with the model and serial number of the pump when ordering
repair parts.
This manual deals exclusively with the F and FH 4625 pumps.
Figure 1 illustrates the overall appearance of the pumps in
this manual.
UNMOUNTED PUMP AND UNIT MODEL NUMBERS
ROTATION: Viking pumps operate equally well in a clock-
wise or counterclockwise rotation. Shaft rotation determines
which port is suction and which is discharge. Port in the area
where the pumping elements (gear teeth) come out of mesh
is suction port.
FIGURE 1
SERIES 4625 PUMP
F AND FH SIZES
SPECIAL INFORMATION
DANGER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.)
Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor, turbine,
engine, etc.) has been “locked out” or
made non-operational so that it cannot
be started while work is being done on
pump.
3. That you know what liquid the pump
has been handling and the precautions
necessary to safely handle the liquid.
Obtain a material safety data sheet
(MSDS) for the liquid to be sure these
precautions are understood.
Failure to follow above listed
precautionary measures may result in
serious injury or death.
Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com
ABRASIVE LIQUID PUMPS
SERIES 4625
SIZES F - FH
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - TECHNICAL SERVICE MANUAL

SECTION TSM 410.1PAGE 1 Of 5ISSUE DVIKING PUMP, INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USATECHNICAL SERVICE MANUAL CONTENTSINTR

Page 2

SECTION TSM 410.1 ISSUE D PAGE 2 OF 5BEFORE opening any liquid chamber (pumping chamber, reservoir, relief valve adjusting cap fitting, etc.) be su

Page 3 - DISASSEMBLY

SECTION TSM 410.1 ISSUE D PAGE 3 OF 5MAINTENANCEModel 4625 pumps are designed for long, trouble free life under a wide variety of application condi

Page 4 - ASSEMBLY

SECTION TSM 410.1 ISSUE D PAGE 4 OF 5FIGURE 3CUTAWAY VIEW OF SERIES 4625ITEM NAME OF PART ITEM NAME OF PART ITEM NAME OF PART1 Locknut 6 Grease Fit

Page 5

SECTION TSM 410.1PAGE 5 OF 5ISSUE DVIKING PUMP, INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA© 3/2013 Viking Pump Inc. All rights