SECTION TSM 630.1 ISSUE F PAGE 13 OF 14
NOTE:
1. Heat cartridges, temperature probes, and controllers
must be wired by a licensed electrician to meet local
codes.
2. Heat cartridges require 240VAC, 1 Phase, 60 Hz or
220VAC, 1 Phase, 50 Hz power supply.
3. Heat cartridges are UL, CSA, & CE marked, RoHs
compliant.
4. Heat cartridges and cables are water resistant but not
water proof. They need to be installed in a protected
area.
5. To make sure that the liquid within the pump is melted
and to avoid damage to the pump, do not start the pump
until the set point temperature has been reached.
6. Several factors such as the size of pump, the set point
temperature, and the insulation will affect the amount
of time it will take for the pump to reach the set point
temperature. Typically it will take 3-4 hours for the pump
to reach its set point temperature.
7. Do not use heat cartridges with different watt densities
from those supplied by Viking. Changing watt densities
may result in localized over or under heating.
8. The thermocouple or temperature probe must be
installed in the bracket location shown in Figure XX
below. Any other location may result in localized over or
under heating.
9. Please see TSM 630.4 for technical information on the
Viking supplied controller for the heat cartridges.
10. The wires for the heat cartridges can be joined together
in a junction box, and a single wire from the junction box
can be connected to the controller.
11. WARNING Heat cartridges will be hot. Do not touch
pump or heat cartridges until they have been allowed to
cool.
FIGURE 13 - HEAT CARTRIDGE AND THERMOCOUPLE LOCATIONS
TABLE 2 - NUMBER OF HEAT CARTRIDGES IN EACH PUMP MODEL
Dimensions - K through LL Sizes – Electrically Heated – Non Jacketed
Model
Bracket Heater to Port
Center Line (DD)
Temp Probe to Port
Center Line (CC)
Head Heater to Port
Center Line (EE)
Required to Remove Heater
(AA) (BB)
Inch mm Inch mm Inch mm Inch mm Inch mm
K124E
4.14 105.16 4.88 123.95 5.66 143.76 8.13 206.50 7.75 196.85
KK124E
L124E
4.92 124.97 5.62 142.75
5.71 145.03
7.00 177.80
6.25 158.75
LQ124E 5.75 146.05
LL124E 6.25 158.75 6.75 171.45
AA
BB
EE
DD
CC
(Top View)
Wattage by Pump Size
Pump Size Number of Heaters in Head Number of Heaters in Bracket Total Wattage
K 3 2 690
KK 3 2 690
L 2 2 1200
LQ 2 2 1200
LL 2 2 1250